LOAD CELL
We are instrumental in offering our clients a comprehensive range of Load Cell. Our range is manufactured using premium quality raw material and is known for its durability and high efficiency.
Multi Load Cell
UP 1T1H4 | 1000kg | 100g | 1200 x 1200mm | |
UP 2T2H4 | 2000kg | 200g | 1000 x 1000mm | |
UP 2T2D1H4 | 2000kg | 200g | 1200 x 1200mm | |
UP 2T2D2 H4 | 2000Kg | 200g | 1500 x 1500mm | |
UP 2T2D3H4 | 2000Kg | 200g | 1800 x 1800mm | |
UP 2T2D4H4 | 2000Kg | 200g | 2000 x 2000mm | |
UP 3T5H4 | 3000Kg | 500g | 1500 x 1500mm | |
UP 3T5D1H4 | 3000Kg | 500g | 1800 x 1800mm | |
UP 5T1D1H4 | 5000Kg | 1kg | 2000 x 2000mm |
Load Cell
Capacities: • 200, 300, 500, 700, • 1000, 2000 gm |
Application: • Precision balances, electronic scale, • by single load cell |
1. | Rate Load Capacity | 10,15,20,30,50 tons | |
2. | Input Resistance | 800 +/- 30 W | |
3. | Output Resistance | 700+/- 5 W | |
4. | Excitation Recommended | Max 15 Volts | |
5. | Rated Output | 3.0 +/- 10% mv/v | |
6. | Non-Linearity | +/- 0.03% of applied load | |
7. | Hysterisis | +/- 0.03% of applied load | |
8. | Thermal Effect on Zero | 0.05% of applied load/10 deg C | |
9. | Thermal Effect on Sensitivity | 0.03% of applied load/10 deg C | |
10. | Insulation Resistance | > 1000 m W | |
11. | Creep at 20 Minutes | +/- 0.05 % of applied load | |
12. | Temperature Range Operative | 0 deg. C to 50 deg. C | |
13. | Safe Load | 150% of rated capacity | |
14. | Ultimate Load | 300% rated capacity | |
15. | Protection Clause | IP 67 |